2020-03-29 09:16:53 +00:00
|
|
|
echo on
|
|
|
|
|
|
|
|
rem Temporarily hardcoded:
|
|
|
|
set TARGET=Visual Studio 2019
|
|
|
|
set SHORTNAME=vs2019
|
|
|
|
|
|
|
|
rem Initialize Visual Studio variables
|
|
|
|
if "%TARGET%" == "Visual Studio 2017" call "C:\Program Files (x86)\Microsoft Visual Studio\2017\Community\VC\Auxiliary\Build\vcvars64.bat"
|
|
|
|
if "%TARGET%" == "Visual Studio 2019" call "C:\Program Files (x86)\Microsoft Visual Studio\2019\Community\VC\Auxiliary\Build\vcvars64.bat"
|
|
|
|
|
|
|
|
rem Installing tools
|
|
|
|
rem only for appveyor:
|
|
|
|
rem cinst unrar -y
|
|
|
|
rem cinst unzip -y
|
|
|
|
rem cinst innosetup -y
|
|
|
|
|
|
|
|
rem Installing UnrealIRCd dependencies
|
|
|
|
cd \projects
|
2022-01-15 05:16:34 +00:00
|
|
|
mkdir unrealircd-6-libs
|
|
|
|
cd unrealircd-6-libs
|
|
|
|
curl -fsS -o unrealircd-libraries-6-devel.zip https://www.unrealircd.org/files/dev/win/libs/unrealircd-libraries-6-devel.zip
|
|
|
|
unzip unrealircd-libraries-6-devel.zip
|
|
|
|
copy dlltool.exe \users\user\worker\unreal6-w10\build /y
|
2020-03-29 09:16:53 +00:00
|
|
|
|
2022-01-15 05:16:34 +00:00
|
|
|
rem for appveyor, use: cd \projects\unrealircd
|
|
|
|
cd \users\user\worker\unreal6-w10\build
|
2020-03-29 09:16:53 +00:00
|
|
|
|
2022-01-15 05:16:34 +00:00
|
|
|
rem Install 'unrealircd-tests'
|
|
|
|
cd ..
|
|
|
|
rd /q/s unrealircd-tests
|
|
|
|
git clone -q --branch unreal60 https://github.com/unrealircd/unrealircd-tests.git unrealircd-tests
|
|
|
|
if %ERRORLEVEL% NEQ 0 EXIT /B 1
|
|
|
|
cd build
|
2020-03-29 09:16:53 +00:00
|
|
|
|
2022-01-15 05:16:34 +00:00
|
|
|
rem Now the actual build
|
|
|
|
rem - First this, otherwise JOM will fail
|
|
|
|
IF NOT EXIST src\version.c nmake -f Makefile.windows CONF
|
|
|
|
rem - Then build most of UnrealIRCd.exe etc
|
2022-04-03 15:09:29 +00:00
|
|
|
call extras\build-tests\windows\compilecmd\%SHORTNAME%.bat UNREALSVC.EXE UnrealIRCd.exe unrealircdctl.exe
|
2022-01-15 05:16:34 +00:00
|
|
|
rem - It will fail due to missing symbolfile, which we create here..
|
2020-03-29 09:16:53 +00:00
|
|
|
nmake -f makefile.windows SYMBOLFILE
|
2022-01-15 05:16:34 +00:00
|
|
|
rem - Then we finalize building UnrealIRCd.exe: should be no error
|
2022-04-03 15:09:29 +00:00
|
|
|
call extras\build-tests\windows\compilecmd\%SHORTNAME%.bat UNREALSVC.EXE UnrealIRCd.exe unrealircdctl.exe
|
2022-01-15 05:16:34 +00:00
|
|
|
if %ERRORLEVEL% NEQ 0 EXIT /B 1
|
|
|
|
rem - Build all the modules (DLL files): should be no error
|
|
|
|
call extras\build-tests\windows\compilecmd\%SHORTNAME%.bat MODULES
|
2020-03-29 09:16:53 +00:00
|
|
|
if %ERRORLEVEL% NEQ 0 EXIT /B 1
|
|
|
|
|
2021-01-08 23:15:08 +00:00
|
|
|
rem Compile dependencies for unrealircd-tests -- this doesn't belong here though..
|
2022-01-15 05:16:34 +00:00
|
|
|
copy ..\unrealircd-tests\serverconfig\unrealircd\modules\fakereputation.c src\modules\third /Y
|
2021-01-08 23:15:08 +00:00
|
|
|
call extras\build-tests\windows\compilecmd\%SHORTNAME%.bat CUSTOMMODULE MODULEFILE=fakereputation
|
|
|
|
if %ERRORLEVEL% NEQ 0 EXIT /B 1
|
|
|
|
|
2022-01-15 05:16:34 +00:00
|
|
|
rem Convert c:\dev to c:\projects\unrealircd-6-libs
|
2020-03-29 09:16:53 +00:00
|
|
|
rem TODO: should use environment variable in innosetup script?
|
2022-01-15 05:16:34 +00:00
|
|
|
sed -i "s/c:\\dev\\unrealircd-6-libs/c:\\projects\\unrealircd-6-libs/gi" src\windows\unrealinst.iss
|
2020-03-29 09:16:53 +00:00
|
|
|
|
|
|
|
rem Build installer file
|
|
|
|
"c:\Program Files (x86)\Inno Setup 5\iscc.exe" /Q- src\windows\unrealinst.iss
|
|
|
|
if %ERRORLEVEL% NEQ 0 EXIT /B 1
|
|
|
|
|
|
|
|
rem Show some proof
|
|
|
|
ren mysetup.exe unrealircd-dev-build.exe
|
|
|
|
dir unrealircd-dev-build.exe
|
|
|
|
sha256sum unrealircd-dev-build.exe
|
|
|
|
|
|
|
|
rem Kill any old instances, just to be sure
|
|
|
|
taskkill -im unrealircd.exe -f
|
|
|
|
sleep 2
|
|
|
|
rem Just a safety measure so we don't end up testing
|
|
|
|
rem some old version...
|
2022-01-15 05:16:34 +00:00
|
|
|
del "C:\Program Files\UnrealIRCd 6\bin\unrealircd.exe"
|
2020-03-29 09:16:53 +00:00
|
|
|
|
|
|
|
echo Running installer...
|
|
|
|
start /WAIT unrealircd-dev-build.exe /VERYSILENT /LOG=setup.log
|
|
|
|
if %ERRORLEVEL% NEQ 0 goto installerfailed
|
|
|
|
|
|
|
|
rem Upload artifact
|
|
|
|
rem appveyor PushArtifact unrealircd-dev-build.exe
|
|
|
|
rem if %ERRORLEVEL% NEQ 0 EXIT /B 1
|
|
|
|
|
2022-01-15 05:16:34 +00:00
|
|
|
cd ..\unrealircd-tests
|
2020-03-29 09:16:53 +00:00
|
|
|
dir
|
|
|
|
|
2021-06-19 15:52:51 +00:00
|
|
|
rem All tests except db:
|
2020-03-29 09:16:53 +00:00
|
|
|
"C:\Program Files\Git\bin\bash.exe" ./runwin
|
|
|
|
if %ERRORLEVEL% NEQ 0 EXIT /B 1
|
|
|
|
|
2021-06-19 15:52:51 +00:00
|
|
|
rem Test unencrypted db's:
|
|
|
|
"C:\Program Files\Git\bin\bash.exe" ./runwin -boot tests/db/writing/*
|
|
|
|
if %ERRORLEVEL% NEQ 0 EXIT /B 1
|
|
|
|
"C:\Program Files\Git\bin\bash.exe" ./runwin -keepdbs -boot tests/db/reading/*
|
|
|
|
if %ERRORLEVEL% NEQ 0 EXIT /B 1
|
|
|
|
|
|
|
|
rem Test encrypted db's:
|
|
|
|
"C:\Program Files\Git\bin\bash.exe" ./runwin -include db_crypted.conf -boot tests/db/writing/*
|
|
|
|
if %ERRORLEVEL% NEQ 0 EXIT /B 1
|
|
|
|
"C:\Program Files\Git\bin\bash.exe" ./runwin -include db_crypted.conf -keepdbs -boot tests/db/reading/*
|
|
|
|
if %ERRORLEVEL% NEQ 0 EXIT /B 1
|
|
|
|
|
2020-03-29 09:16:53 +00:00
|
|
|
goto end
|
|
|
|
|
2021-06-19 15:52:51 +00:00
|
|
|
|
|
|
|
|
2020-03-29 09:16:53 +00:00
|
|
|
:installerfailed
|
|
|
|
type setup.log
|
|
|
|
echo INSTALLATION FAILED
|
|
|
|
EXIT /B 1
|
|
|
|
|
|
|
|
:end
|